Comprehensive Power Solutions for Ghana EPC
TSTY Electric Co., Ltd. is a Chinese manufacturer with over 30 years of experience in power equipment production. we provide power transformers, prefabricated substations, medium and low voltage switchgear, and battery energy storage systems to EPC contractors, engineering general contractors, industrial project developers, and energy project investors in Ghana.
TSTY's production base is located in Jia County, Pingdingshan City, Henan Province, China, covering a total area of approximately 500,000 square meters. It has a CNAS-accredited laboratory and holds 158 patents, including 67 invention patents.
The company's main products include:
- Oil-immersed and dry-type transformers, with a manufacturing capacity up to 100 MVA.
- Prefabricated and box-type substations, with a maximum capacity of 10,000 kVA.
- 12 kV, 24 kV, and 40.5 kV medium-voltage switchgear and low-voltage switchgear assemblies.
- Industrial and commercial energy storage, photovoltaic-energy storage systems, and large-scale containerized energy storage products.
TSTY provides equipment selection, technical documentation, product manufacturing, factory testing, export delivery, and project technical support for EPC projects in Ghana. The company has extensive experience in Ghanaian market and can provide corresponding power equipment configuration solutions based on the specific needs of each project.

Why did Ghana's EPC contractor choose TSTY Electric?
For EPC projects in Ghana, technical coordination among transformers, switchgear, package substations, and energy storage equipment is of critical importance.
TSTY’s strength lies not merely in supplying individual products, but in its comprehensive manufacturing capability—encompassing everything from transformers and complete switchgear assemblies to energy storage systems—which enables the company to provide a more complete equipment package for such projects.
|
Manufacturing and R&D Capabilities |
Enterprise Data |
|
Industry Experience |
30+ years |
|
Total land area of the production base |
500,000 m² |
|
laboratory |
CNAS accredited laboratories |
|
Total number of patents |
158 items |
|
Invention Patent |
67 items |
|
Participate in national standards |
19 items |
|
Participate in industry standards |
22 items |
|
Participate in Group Standards |
35 items |
|
Countries to which products are exported |
100+ |
Four power equipments for EPC procurement requirements
Equipment scope for a 33/11 kV substation in Ghana
A 33/11 kV EPC substation combines a power transformer, MV switchgear, a 400 V distribution board and protection — plus the civil works the contractor controls. The table below shows what TSTY supplies for that scope and the standard each item is tested to, so the equipment list can be matched to a bill of quantities directly.
|
Equipment |
Typical rating |
Role in the substation |
Standard |
|
Power transformer |
5–100 MVA, 33/11 kV |
Steps 33 kV down to 11 kV |
IEC 60076 |
|
Distribution transformer |
30–2,500 kVA, 11/0.415 kV |
Final step to low voltage |
IEC 60076 |
|
Compact substation |
up to 10,000 kVA |
Transformer, RMU and LV board in one enclosure |
IEC 62271-202 |
|
MV switchgear |
11 kV / 33 kV, AIS or GIS |
Switching, protection and metering |
IEC 62271-200 |
|
LV switchboard |
400 V |
Distribution, motor control, changeover |
IEC 61439 |
|
Battery storage |
100 kWh – 5 MWh |
Peak shaving, diesel reduction, solar firming |
UL 9540A, IEC |
All four product lines are manufactured in Jiaxian, Henan, on a 500,000 m² site transformer and switchgear workshops and a CNAS-accredited testing laboratory. Supplying them from one factory is what removes the interface risk between three separate vendors.
Power Transformers
Power transformers for 33/11 kV and 161 kV substations
The power transformers for 33/11 kV substations are a standard TSTY product, built from 5 MVA to 100 MVA with ONAN or ONAF cooling, off-circuit or on-load tap changers, and Dyn11 or YNd11 vector groups. Impedance is set per project so that downstream fault levels stay inside the switchgear rating, and loss values are guaranteed in the contract rather than quoted as typical.
|
Rating |
Voltage ratio |
Cooling |
Short-circuit impedance |
Vector group |
Tapping |
|
5 MVA |
33/11 kV |
ONAN |
7.5% (per project) |
Dyn11 |
OCTC ±2 × 2.5% |
|
10 MVA |
33/11 kV |
ONAN / ONAF |
8% (per project) |
Dyn11 / YNd11 |
OLTC ±8 × 1.25% |
|
20 MVA |
33/11 kV |
ONAF |
9% (per project) |
YNd11 |
OLTC ±8 × 1.25% |
For 161 kV interconnection work, transformers are built to the same IEC 60076 regime with impulse-tested windings and site-assembled bushings; those units are quoted individually because transport and erection planning decide the design as much as the electrical specification does.
Distribution transformers at 11/0.415 kV
Distribution transformers from 30 kVA to 2,500 kVA are the highest-volume item on most Ghanaian EPC scopes: factory buildings, industrial parks, mines and utility reinforcement. TSTY builds them at 11/0.415 kV with Dyn11 connection, ONAN cooling and OCTC ±5% tapping, matching the 415/240 V low-voltage network used by ECG and by private industrial estates.
Loss performance, not price, is what determines lifecycle cost on these units. Measured values for two standard ratings are listed below; the 2,000 kVA figures are the guaranteed values from the TÜV Rheinland certificate of conformity.
|
Rating |
Voltage |
No-load loss |
Load loss at 75 °C |
Impedance |
Notes |
|
500 kVA |
11/0.415 kV |
680 W |
5,410 W |
4% |
Routine-tested per unit |
|
1,000 kVA |
11/0.415 kV |
1,150 W |
10,300 W |
4.5% |
Routine-tested per unit |
|
2,000 kVA |
21/0.8 kV |
≤ 1,305 W |
≤ 15 kW |
6% ±10% |
Guaranteed values, TÜV CoC AK 50728320 0001 |

Dry-type transformers for indoor substations
Dry-type transformers run from 30 kVA to 31,500 kVA at 10/11 kV, 20/22 kV and 33/35 kV, and are specified where oil is unacceptable: basement substations, plant rooms, tunnels, and buildings where a fire load or an oil-containment sump is not permitted. Cast-resin construction removes the oil handling and oil testing that liquid-filled units require through their life.
Losses, impedance and tap ranges
|
Aspect |
Oil-immersed |
Dry-type |
When to choose |
|
Cooling |
ONAN / ONAF |
AN / AF |
Oil where outdoor space and maintenance access exist |
|
Fire behaviour |
Oil-filled, needs bunding |
Self-extinguishing cast resin |
Dry-type for indoor, basement, densely occupied buildings |
|
Typical impedance |
4–6.5% distribution; 7.5–10% power |
6% |
Match to upstream protection settings |
|
Tapping |
OCTC ±5%, or OLTC ±8 × 1.25% |
OCTC ±2 × 2.5% |
OLTC where the supplied voltage swings daily |
|
Condition monitoring |
Oil BDV, moisture, DGA |
Winding temperature, partial discharge |
Oil units need an oil-testing routine on site |
Compact and prefabricated substations
A compact substation puts the transformer, a ring main unit, the LV distribution board and the protection relays into one factory-assembled enclosure, tested as a unit before shipment. TSTY builds them up to 10,000 kVA with a 40.5 kV high-voltage side and a 12 kV or 0.69 kV low-voltage side, rated IP54 or IP55 and tested for −40 °C to +40 °C ambient.
The reason EPC contractors specify them is schedule and civil works, not floor area alone:
|
Aspect |
Compact substation |
Conventional substation building |
|
Footprint |
6–12 m² for 630–2,000 kVA |
40–80 m² including switch room and cable basement |
|
Civil works |
Concrete plinth and cable entry only |
Building, cable trench, ventilation, fire separation |
|
Site installation |
1–3 days after delivery |
6–10 weeks including building works |
|
Relocation |
Possible as a complete unit |
Not practical |
|
Rating range |
up to 10,000 kVA |
unrestricted |
|
Factory testing |
Transformer, RMU and LV board tested together |
Each item tested separately by its own supplier |
That last row is the one that changes project risk: one factory acceptance test covers the whole assembly, so interface faults between transformer and switchgear surface before shipment rather than during energisation.

MV and LV switchgear
11 kV and 33 kV switchgear
TSTY supplies metal-clad and gas-insulated switchgear for 12 kV, 24 kV and 40.5 kV systems: KYN28A-12 and KYN28A-24 for indoor metal-clad boards, KYN61-40.5 where 33 kV is required, HXGN-12 ring main units for compact substations, and GIS where space or pollution demands a sealed design.
|
Model |
Voltage |
Type |
Typical application |
Standard |
|
KYN28A-12 |
12 kV |
Metal-clad, withdrawable |
11 kV incomers and feeders |
IEC 62271-200 |
|
KYN28A-24 |
24 kV |
Metal-clad, withdrawable |
20/22 kV systems |
IEC 62271-200 |
|
KYN61-40.5 |
40.5 kV |
Metal-clad, withdrawable |
33 kV substations |
IEC 62271-200 |
|
HXGN-12 |
12 kV |
Ring main unit |
Compact substations, distribution rings |
IEC 62271-200 |
|
GIS |
12–40.5 kV |
Gas-insulated |
Confined space, high pollution |
IEC 62271-200 |
|
BlokSeT |
400 V |
LV switchboard |
Main distribution, motor control |
IEC 61439 |
Rated current and short-circuit ratings are selected per project: [C7]. Because the switchgear and the transformer come from the same factory, the through-fault rating of the board and the impedance of the transformer are checked against each other before the drawings are released, instead of after delivery.
LV main switchboards at 400 V
Low-voltage boards are built on Schneider BlokSeT technology, with ACB or MCCB incomers, motor control centres, automatic transfer switching and capacitor banks for power-factor correction. They are assembled and routine-tested in the same workshop as the MV panels, which keeps the earthing and interlocking design consistent between the two voltage levels.
Protection and metering interface
Protection is coordinated across the transformer, the MV feeder and the LV main breaker: overcurrent and earth-fault settings on the MV side are chosen against the transformer damage curve, and the LV breaker is set below the transformer through-fault capability. Where the EPC provides its own protection study, TSTY issues the relay setting files and the CT/VT ratios needed to complete it.
Battery energy storage for EPC projects
Containerised lithium storage from 100 kW / 101 kWh to 1,000 kW / 5,015 kWh covers the three cases EPC contractors bring to Ghanaian sites: shaving diesel consumption at mines, firming a solar plant, and cutting demand charges at industrial facilities. Systems ship with PCS, EMS and fire-suppression design integrated.
33/11kV Transformer & Substation Application
|
Package |
Contents |
Typical project |
Voltage |
|
Distribution substation package |
Transformer, RMU, LV board, protection |
Factory, industrial park, commercial development |
33/11 kV, 11/0.415 kV |
|
Industrial plant package |
Power transformer, MV switchgear, LV distribution |
Mine, cement plant, processing facility |
33 kV or 11 kV |
|
Solar-plus-storage package |
Step-up transformer, MV switchgear, battery storage |
IPP, mine hybrid plant, captive solar |
11/33 kV |
TSTY’s Comprehensive Equipment Solutions for EPC Projects in Ghana

- Oil-immersed or dry-type transformers
- Medium voltage KYN28A / GIS / Ring main unit

- Photovoltaic Step-Up Transformer
- Prefabricated Substation
- Medium Voltage Switchgear
- Supporting Low Voltage Electrical Equipment

- C&I Energy Storage System
- Battery System and Supporting Control Equipment
- PCS / EMS System (determined based on product and project scope)
- Step-up Transformer
- Medium and Low Voltage Switchgear

- Industrial Power Transformers
- Medium Voltage Switchgear
- Low Voltage Distribution and Control Cabinets
- Prefabricated Substations
TSTY’s Project Experience in the Ghanaian Market
TSTY possesses relevant experience with mining projects in Ghana, covering various mining applications and electrical equipment designed for the mining sector.
Mining projects demand high levels of power supply reliability, equipment adaptability, and robustness for on-site operating conditions. TSTY provides tailored transformer and power distribution equipment configurations based on project technical specifications and actual load requirements.
TSTY can supply the following, as required by your project:
- Product technical data sheets.
- Transformer loss data.
- Type test reports for the relevant products.
- Product compliance documentation.
- Equipment outline drawings and technical specifications.
- Documentation for project tenders and technical submittals.
Furthermore, TSTY can provide distribution transformer loss test data and energy efficiency label designs to assist clients with local registration and compliance filings in Ghana. For project tenders and technical evaluations, TSTY can prepare comprehensive technical submittal packages based on the specific product data.
TSTY’s Manufacturing, Delivery, and After-Sales Support
TSTY has a production base in Henan, China, primarily manufacturing transformers, box-type substations, high- and low-voltage switchgear, and energy storage equipment; it also operates a laboratory accredited by CNAS.
|
Items |
TSTY Current Conditions |
|
Factory location |
Jia County, Pingdingshan City, Henan Province |
|
Conventional transformer lead time |
15–25 days |
|
Default port of shipment |
Qingdao Port can be adjusted according to customer requirements. |
|
Payment methods |
T/T, L/C or other Negotiable payment methods |
|
Payment Terms |
100% prepayment, 30% prepayment + 70% before shipment, or other negotiated payment terms. |
|
Standard warranty |
1 year |
|
Optional warranty |
2-5 years |
|
Spare parts supply |
Shipped from Chinese factory, approximately 2–4 weeks. |
Installation, testing and handover
Installation is executed by the EPC; TSTY provides supervision, oil processing and the pre-commissioning programme. The checks below are the ones that most often stop energisation when they are skipped.
|
Test |
What it confirms |
|
Insulation resistance |
Winding and bushing integrity after transport |
|
Turns ratio and vector group |
Nameplate conformity and parallel-operation suitability |
|
Winding resistance |
Connection quality and contact resistance |
|
Short-circuit impedance |
Match to the protection study |
|
Oil breakdown voltage and moisture |
Oil condition before energisation |
|
Protection relay settings |
Coordination with the upstream feeder |
|
Interlock and safety shutter checks |
Operator safety under fault conditions |
|
Earthing continuity |
Substation earthing integrity |
Handover documentation includes as-built drawings, routine test records, O&M manuals, a spare-parts list and the commissioning report. Commissioning engineers are dispatched from China, and spare parts ship from the factory, typically within 2–4 weeks.
Schedule risks and how we control them
Three failure modes account for most equipment-related delay on Ghanaian EPC projects. Each has a control that is written into the purchase order rather than promised in a meeting.
|
Risk |
What it costs the EPC |
How TSTY controls it |
|
Delivery slips against a construction milestone |
Liquidated damages, idle labour, re-sequenced works |
Production slot locked at purchase order; weekly progress report with photographs |
|
Specification deviation found at drawing approval |
Re-design, 4–6 week delay, re-quote |
Clause-by-clause compliance review before the order is placed, not after |
|
Customs delay at Tema |
Storage charges, missed energisation date |
Pre-shipment document review with the clearing agent; advance ruling where classification is unclear |
FAQ for EPC Clients in Ghana